排序:
共找到24条结果
  • 1000MW超超临界汽轮机低压II转子高速动平衡研究

    对1000MW机组低压II转子高速动平衡过程进行了分析,并对动平衡所用设备及转子的平衡方法进行介绍,为今后国内相关百万超超临界机组转子平衡提供参考和借鉴.
    李立波,邹本艳,李雅武,张修寰 - 汽轮机技术
    文章来源: 万方数据
  • The aerodynamic braking is a clean and non-adhesion braking, and can be used to provide extra braking force during high-speed emergency braking. The research of aerodynamic braking has attracted more and more attentions in recent years. However, most researchers in this field focus on aerodynamic effects and seldom on issues of position control of the aerodynamic braking board. The purpose of this paper is to explore position control optimization of the braking board in an aerodynamic braking prototype. The mathematical models of the hydraulic drive unit in the aerodynamic braking system are analyzed in detail, and the simulation models are established. Three control functions-constant, linear, and quadratic-are explored. Two kinds of criteria, including the position steady-state error and the acceleration of the piston rod, are used to evaluate system performance. Simulation results show that the position steady state-error is reduced from around 12–2 mm by applying a linear instead of a constant function, while the acceleration is reduced from 25.71–3.70 m/s2 with a quadratic control function. Use of the quadratic control function is shown to improve system performance. Experimental results obtained by measuring the position response of the piston rod on a test-bench also suggest a reduced position error and smooth movement of the piston rod. This implies that the acceleration is smaller when using the quadratic function, thus verifying the effectiveness of control schemes to improve to system performance. This paper proposes an effective and easily implemented control scheme that improves the position response of hydraulic cylinders during position control.
     - 中国机械工程学报
    文章来源: 万方数据
  • The methods of improving the dynamic performance of high speed on/off solenoid valve include increasing the magnetic force of armature and the slew rate of coil current, decreasing the mass and stroke of moving parts. The increase of magnetic force usually leads to the decrease of current slew rate, which could increase the delay time of the dynamic response of solenoid valve. Using a high voltage to drive coil can solve this contradiction, but a high driving voltage can also lead to more cost and a decrease of safety and reliability. In this paper, a new scheme of parallel coils is investigated, in which the single coil of solenoid is replaced by parallel coils with same ampere turns. Based on the mathematic model of high speed solenoid valve, the theoretical formula for the delay time of solenoid valve is deduced. Both the theoretical analysis and the dynamic simulation show that the effect of dividing a single coil into N parallel sub-coils is close to that of driving the single coil with N times of the original driving voltage as far as the delay time of solenoid valve is concerned. A specific test bench is designed to measure the dynamic performance of high speed on/off solenoid valve. The experimental results also prove that both the delay time and switching time of the solenoid valves can be decreased greatly by adopting the parallel coil scheme. This research presents a simple and practical method to improve the dynamic performance of high speed on/off solenoid valve.
     - 中国机械工程学报
    文章来源: 万方数据
  • Cavitation of centrifugal blood pump is a serious problem accompany with the blocking failure of short inlet cannula.However,hardly any work has been seen in published literature on this complex cavitation phenomenon caused by the coupling effect of inlet cannula blocking and pumps suction.Even for cavitation studies on ordinary centrifugal pumps,similar researches on this issue are rare.In this paper,the roles of throttling,rotation speed and fluid viscosity on bubble inception and intensity in a centrifugal blood pump are studied,on the basis of experimental observations.An adjustable throttle valve installed just upstream blood pump inlet is used to simulate the throttling effect of the narrowed inlet cannula.The rotation speed is adjusted from 2 600 r/min to 3 200 r/min.Glycerin water solutions are used to investigate the influences of kinetic viscosity.Bubbles are recorded with a high-speed video camera.Direct observation shows that different from cavitation in industrial centrifugal pumps,gas nuclei appears at the nearby of vane leading edges while throttling is light,then moves upstream to the joint position of inlet pipe and pump with the closing of the valve.It's found that the critical inlet pressure,obtained when bubbles are first observed,decreases linearly with viscosity and the slope is independent with rotation speeds;the critical inlet pressure and the inlet extreme pressure which is obtained when the throttle valve is nearly closed,fall linearly with rotation speed respectively and the relative pressure between them is independent with rotation speed and fluid viscosity.This paper studies experimentally on cavitation in centrifugal blood pump that caused by the failure of assembled short inlet cannula,which may beneficial the design of centrifugal blood pump with inlet cannula.
     - 中国机械工程学报
    文章来源: 万方数据
  • 水平衡测试技术研究及应用

    水平衡测试是加强用水科学管理,最大限度地节约用水与合理用水的一项基础工作.解释了水平衡测试的定义及开展测试工作的依据,分析了水平衡测试参数之间关系,介绍了水平衡测试的方法,结合承德市中心医院水平衡测试实例,分析其用水现状,为制定用水定额和计划用水量指标,提供了较准确的基础数据,为今后节约用水提出了合理化的建议.
    张东莱,王占升,卢峰 - 南水北调与水利科技
    文章来源: 万方数据
  • Mechanical Properties and Microstructure Evolution of Cold-deformed High-nitrogen Nickel-free Austenitic Stainless Steel during Annealing

    The mechanical properties and microstructure evolution of cold-deformed CrMnN austenitic stainless steel annealed in a temperature ranging from 50 ℃ to 650 ℃ for 90 min and at 550 ℃ for different time were investigated by tensile test, micro hardness test, and Transmission Electron Microscope (TEM). The steel was strengthened when it got annealed at temperatures ranging from 100 ℃ to 550 ℃, while it was softened when it got annealed at temperatures ranging from 550 ℃ to 650 ℃. Annealing temperature had stronger effect on mechanical properties than annealing time. TEM observations showed that nano-sized precipitates formed when the steel was annealed at 150 ℃ for 90 min, but the size and density of precipitates had no noticeable change with annealing temperature and time. Recrystallization occurred when the steel was annealed at temperatures above 550 ℃ for 90 min, and its scale increased with annealing temperature. Nano-sized annealing twins were observed. The mechanisms that controlled the mechanical behaviors of the steel were discussed.
    徐明舟,刘春明 - 武汉理工大学学报(材料科学版)(英文版)
    文章来源: 万方数据
  • The competition of surface and subsurface crack initiation induced failure is critical to understand very high cycle fatigue(VHCF)behavior,which necessitates the elucidation of the underlying mechanisms for the transition of crack initiation from surface to interior defects.Crack initiation potential in materials containing defects is investigated numerically by focusing on defect types,size,shape,location,and residual stress influences.Results show that the crack initiation potency is higher in case of serious property mismatching between matrix and defects,and higher strength materials are more sensitive to soft inclusions(elastic modulus lower than the matrix).The stress localization around inclusions are correlated to interior crack initiation mechanisms in the VHCF regime such as inclusion-matrix debonding at soft inclusions and inclusion-cracking for hard inclusions(elastic modulus higher than the matrix).It is easier to emanate cracks from the subsurface pores with the depth 0.7 times as large as their diameter.There exists an inclusion size independent region for crack incubation,outside which crack initiation will transfer from the subsurface soft inclusion to the interior larger one.As for elliptical inclusions,reducing the short-axis length can decrease the crack nucleation potential and promote the interior crack formation,whereas the long-axis length controls the site of peak stress concentration.The compressive residual stress at surface is helpful to shift crack initiation from surface to interior inclusions.Some relaxation of residual stress can not change the inherent crack initiation from interior inclusions in the VHCF regime.The work reveals the crack initiation potential and the transition among various defects under the influences of both intrinsic and extrinsic factors in the VHCF regime,and is helpful to understand the failure mechanism of materials containing defects under long-term cyclic loadings.
     - 中国机械工程学报
    文章来源: 万方数据
  • The remanufacturing blanks with cracks were considered as irreparable. With utilization of detour effect and Joule heating of pulsed current, a technique to arrest the crack in martensitic stainless steel FV520B is developed. According to finite element theory, the finite element(FE) model of the cracked rectangular specimen is established firstly. Then, based on electro-thermo-structure coupled theory, the distributions of current density, temperature field, and stress field are calculated for the instant of energizing. Furthermore, the simulation results are verified by some corresponding experiments performed on high pulsed current discharge device of type HCPD-I. Morphology and microstructure around the crack tip before and after electro pulsing treatment are observed by optical microscope(OM) and scanning electron microscope(SEM), and then the diameters of fusion zone and heat affected zone(HAZ) are measured in order to contrast with numerical calculation results. Element distribution, nano-indentation hardness and residual stress in the vicinity of the crack tip are surveyed by energy dispersive spectrometer(EDS), scanning probe microscopy(SPM) and X-ray stress gauge, respectively. The results show that the obvious partition and refined grain around the crack tip can be observed due to the violent temperature change. The contents of carbon and oxygen in fusion zone and HAZ are higher than those in matrix, and however the hardness around the crack tip decreases. Large residual compressive stress is induced in the vicinity of the crack tip and it has the same order of magnitude for measured results and numerical calculation results that is 100 MPa. The relational curves between discharge energies and diameters of the fusion zone and HAZ are obtained by experiments. The difference of diameter of fusion zone between measured and calculated results is less than 18.3%. Numerical calculation is very useful to define the experimental parameters. An effective method to prevent further extension of the crack is presented and can provide a reference for the compressor rotor blade remanufacturing.
     - 中国机械工程学报
    文章来源: 万方数据
  • 新疆温宿县地下水水量均衡计算

    以阿克苏地区水文地质普查报告和温宿县地下水资源开发利用规划等相关资料及实地调查、测量等工作取得的原始资料为基础,说明了研究区的水文地质条件,确定计算研究区的地下水水量均衡方程和计算参数,利用搜集到相关数据进行地下水水量均衡计算,计算结果表明:该区地下水补给量略大于排泄量,主要的补给源为河流渠系的入渗和山前侧向人渗;主要排泄量为向下游的排泄量和潜入蒸发量.
    何向东 - 南水北调与水利科技
    文章来源: 万方数据
  • Current researches show that mechanical deformation of seal ring face makes fluid film clearance decrease at high pressure side, thus a divergent clearance is formed and face wear occurs more seriously at the high pressure side than that on the low pressure side. However, there is still lack of published experimental works enough to prove the theoretical results. In this paper, a spiral groove dry gas seal at high pressures is experimentally investigated so as to prove the face wear happened at the high pressure side of seal faces due to the face mechanical deformation, and the wear behavior affected by seal ring structure is also studied. The experimental results show that face wear would occur at the high pressure side of seal faces due to the deformation, thus the leakage and face temperature increase, which all satisfies the theoretical predictions. When sealed pressure is not less than 5 MPa, the pressure can provide enough opening force to separate the seal faces. The seal ring sizes have obvious influence on face wear. Face wear, leakage and face temperature of a dry gas seal with the smaller cross sectional area of seal ring are less than that of a dry gas seal with bigger one, and the difference of leakage rate between these two sizes of seal face width is in the range of 24%–25%. Compared with the effect of seal ring sizes, the effect of secondary O-ring seal position on face deformation and face wear is less. The differences between these two types of dry gas seals with different secondary O-ring seal positions are less than 5.9% when the rotational speed varies from 0 to 600 r/min. By linking face wear and sealing performance changes to the shift in mechanical deformation of seal ring, this research presents an important experimental method to study face deformation of a dry gas seal at high pressures.
    XU Jing,PENG Xudong,BAI Shaoxian,MENG Xiangkai,LI Jiyun - 中国机械工程学报(英文版)
    文章来源: 万方数据
共3页 转到